Error code (错误代码)

1xxx (Microcode checksum

error)

(微码校验错误)

可能故障原因

ServeRAID controller

(阵列卡)

2xxx (Code DRAM error)

(Code DRAM错误)

1. Install download jumpers, flash latest level BIOS and firmware

for controller. Remove jumpers.

(检查download跳线的正确设置,升级阵列卡

的BIOS和firmware到最新版本)

2. ServeRAID controller

(阵列卡)

3000-31XX (Code DRAM error) 1. Install download jumpers, flash latest level BIOS and firmware

(Code DRAM错误) for controller. Remove jumpers.

(检查download跳线的正确设置,升级阵列卡的BIOS

和firmware到最新版本)

2. ServeRAID controller

(阵列卡)

3200 (Code DRAM error)

(Code DRAM错误)

1. Install download jumpers, flash latest level BIOS code and

firmware for controller. Remove jumpers.

(检查download跳线的正确设置,升级阵列卡的BIOS

和firmware到最新版本)

2. ServeRAID controller.

(阵列卡)

3300 (ServeRAID-5i only)

(仅针对5i阵列卡)

穞Install the ServeRAID-5i controller in an extended PCI

option slot. See the documentation that came with the server for

more information.

穞(安装5i阵列卡到指定的PCI插槽)

3E20 (ServeRAID-5i only)

(仅针对5i阵列卡)

1. Remove the ServeRAID-5i controller from its slot and install it

in the proper PCI option slot.

(安装5i阵列卡到指定的PCI插槽)

2. Verify that the ServeRAID-5i controller is supported in this

server.

(确认该服务器能够支持5i阵列卡)

3. ServeRAID-5i controller

(5i阵列卡)

4. System board

(主板)

3E2x 1. Reseat the ServeRAID controller.

(重新安装阵列卡)

2. Flash latest level of BIOS code and firmware for controller.

(升级阵列卡的BIOS和firmware到最新版本)

3. ServeRAID-5i controller

(5i阵列卡)

4. Integrated RAID controller on server

(主板集成的阵列卡)

4xxx thru 5xxx (Code DRAM

error)

(Code DRAM错误)

1. Install download jumpers, flash latest level BIOS code and

firmware for controller; then, remove jumpers.

(检查download跳线的正确设置,升级阵列卡的BIOS

和firmware到最新版本)

2. ServeRAID controller

(阵列卡)

6xxx (Cache DRAM error)

(ServeRAID-4H only)

(Code DRAM错误)

(仅限于4H阵列卡)

1. Reseat daughter card.

(重新安装一下子卡)

2. Install download jumpers, flash latest level BIOS code and

firmware for controller; then, remove jumpers.

(检查download跳线的正确设置,升级阵列卡的BIOS

和firmware到最新版本)

3. ServeRAID controller

(阵列卡)

7xxx thru 8xxx (Host/local PCI

bus interface error)

(PCI BUS报错)

2. If ServeRAID-4x controller, replace controller.

(如果使用的是4系列阵列卡,需要替换掉该设

备)

3. If ServeRAID-5i controller, integrated RAID controller on the

server.

(如果使用5i阵列卡,可能是由于主板集成

1. Flash latest level of BIOS code and firmware for controller.

(升级阵列卡的BIOS和firmware到最新版本)


本文标签: 可能 跳线 设置 集成 主板