admin 管理员组文章数量: 887021
2024年3月14日发(作者:git如何打tag)
Error code (错误代码)
1xxx (Microcode checksum
error)
(微码校验错误)
可能故障原因
ServeRAID controller
(阵列卡)
2xxx (Code DRAM error)
(Code DRAM错误)
1. Install download jumpers, flash latest level BIOS and firmware
for controller. Remove jumpers.
(检查download跳线的正确设置,升级阵列卡
的BIOS和firmware到最新版本)
2. ServeRAID controller
(阵列卡)
3000-31XX (Code DRAM error) 1. Install download jumpers, flash latest level BIOS and firmware
(Code DRAM错误) for controller. Remove jumpers.
(检查download跳线的正确设置,升级阵列卡的BIOS
和firmware到最新版本)
2. ServeRAID controller
(阵列卡)
3200 (Code DRAM error)
(Code DRAM错误)
1. Install download jumpers, flash latest level BIOS code and
firmware for controller. Remove jumpers.
(检查download跳线的正确设置,升级阵列卡的BIOS
和firmware到最新版本)
2. ServeRAID controller.
(阵列卡)
3300 (ServeRAID-5i only)
(仅针对5i阵列卡)
穞Install the ServeRAID-5i controller in an extended PCI
option slot. See the documentation that came with the server for
more information.
穞(安装5i阵列卡到指定的PCI插槽)
3E20 (ServeRAID-5i only)
(仅针对5i阵列卡)
1. Remove the ServeRAID-5i controller from its slot and install it
in the proper PCI option slot.
(安装5i阵列卡到指定的PCI插槽)
2. Verify that the ServeRAID-5i controller is supported in this
server.
(确认该服务器能够支持5i阵列卡)
3. ServeRAID-5i controller
(5i阵列卡)
4. System board
(主板)
3E2x 1. Reseat the ServeRAID controller.
(重新安装阵列卡)
2. Flash latest level of BIOS code and firmware for controller.
(升级阵列卡的BIOS和firmware到最新版本)
3. ServeRAID-5i controller
(5i阵列卡)
4. Integrated RAID controller on server
(主板集成的阵列卡)
4xxx thru 5xxx (Code DRAM
error)
(Code DRAM错误)
1. Install download jumpers, flash latest level BIOS code and
firmware for controller; then, remove jumpers.
(检查download跳线的正确设置,升级阵列卡的BIOS
和firmware到最新版本)
2. ServeRAID controller
(阵列卡)
6xxx (Cache DRAM error)
(ServeRAID-4H only)
(Code DRAM错误)
(仅限于4H阵列卡)
1. Reseat daughter card.
(重新安装一下子卡)
2. Install download jumpers, flash latest level BIOS code and
firmware for controller; then, remove jumpers.
(检查download跳线的正确设置,升级阵列卡的BIOS
和firmware到最新版本)
3. ServeRAID controller
(阵列卡)
7xxx thru 8xxx (Host/local PCI
bus interface error)
(PCI BUS报错)
2. If ServeRAID-4x controller, replace controller.
(如果使用的是4系列阵列卡,需要替换掉该设
备)
3. If ServeRAID-5i controller, integrated RAID controller on the
server.
(如果使用5i阵列卡,可能是由于主板集成
1. Flash latest level of BIOS code and firmware for controller.
(升级阵列卡的BIOS和firmware到最新版本)
版权声明:本文标题:阵列卡报错故障 内容由网友自发贡献,该文观点仅代表作者本人, 转载请联系作者并注明出处:http://www.freenas.com.cn/free/1710365270h571854.html, 本站仅提供信息存储空间服务,不拥有所有权,不承担相关法律责任。如发现本站有涉嫌抄袭侵权/违法违规的内容,一经查实,本站将立刻删除。
发表评论